[Nordale Home Page] [Applications] [Benefits] [Capacity] [Specifications and Features] [Yearly Savings and Payback Analysis]    E-mail: nordale@nordale.com 
[FLUID ELIMINATOR ANIMATION]

Nordale Environmental Engineering

The Nordale Fluid Eliminator evaporates the water portion of water-based wastes.
 

Principles of Operation

* Solution is heated in the tank (1) to boiling (212 deg. F) by a serpentine gas fired burner tube.

* Blower fan (7) draws in room air through both the burner tube (2) and an opening in the lid.(3)

* Air entering the lid is directed through a passage in the floating baffle.(4)

* The air is drawn across the surface (5) of the heated liquid, sweeping away the vapors as they break surface.

* The moisture saturated air passes through the draft diverter (6) and then mixes with the burner exhaust.

* The reduced mixture, environmentally safe, is drawn through the blower (7) and is released up the stack.(8)

* Free oils and oils whose emulsions have been thermally broken float to the surface. They are then evacuated via an overflow trough (9) into an external waste receptacle.

* Precipitated solids settle to the bottom and are easily removed at a convenient clean-out port.(10)